PORTFOLIO

BPM ID Komplett | Additional equipment for BPM, LoCuM-4 and Cables

Technical Description:

In addition to the Beam Position Monitor,
FMB offers the necessary additional equipment for installation of complete BPM-units:

1. The BPM chamber

  • FMB standard solution or according to customer’s specification
  • material: 1.4301 or 304, option: 316LN (flanges)

2. The underframe (column)

  • massive standard column, filling with sand is recommended
  • insulation against variations in temperature
  • special design according to space requirements is possible

3. The LoCuM-4 with cables

  • for analysis of the detected photon currents
  • four-channel low-current monitor and current-voltage converter
  • simultaneous determination of the four independent photocurrents between 100 pA and 1mA
  • controller for internal switch function – remote mode via RS232
  • special double-shielded measurement cable (length about 20 m) is recommended

4. Pinhole Array

  • with frame
  • installation in dipole BPM

5. Appropriate bellow

  • welded bellows ( about 20 membrane pairs (DN35CF) and 30 membrane pairs (DN63CF) ) for motorized stages
  • hydroformed bellows for manual adjustment

6. The motorised H-V-Stage

  • adjustment of the complete pre-set BPM into its accurate measurement position within the Beamline
  • high precision and compactness
  • with stepper motor
  • encoder is recommended, but manual operation is possible (necessary mechanical limitation is installed)

 

Technical Data:

H-, V-Stag e10/10     
Length over all   ≈ 354,4 mm
Width over all   ≈ 195 mm
Height over all   ≈ 215,5 mm … 225,5 mm
Stroke Y (horz.)   10 mm
Stroke Z (vert.)   10 mm
Repeat accuracy with Encoder (option)   ± 0,001 mm
Repeat accuracy with limit switch   ± 0,01 mm
Threaded spindle:    
-Dimension   M12x1
-Normal backlash   0,02 mm
-Pitch error   0,003 mm…0,008 mm
     
Stepper motor    
Company   ORIENTAL
Type   High-torque PK-type
No.   PK268-E2,0B
Holding Torque   1,35 Nm
Current per Phase   2 A
Voltage   4,5 VDC
Resitance per Phase   2,25 Ω
Angle per fullstep   1,8°
Repeat accuracy with Encoder(optional)   ± 0,001mm
Step mode   Full / half / micro
Connection motor   Coninvers RC-09P1N324100
Connection limit switch   Coninvers RC-12P1N324100
     
Encoder (option)    
Company   Renishaw
Type   RGH24
Resolution   5 μm … 0,1μm
Signal   TTL RS-422
Current   120 mA (150 mA)
Voltage   5 VDC ±5%
Connection   Sub-D 15 Male

 

Datasheet BPM_ID_Komplett_LoCuM-Additional_equipment

JUX_PORTFOLIO_PRO_DATE
September 9, 2022
JUX_PORTFOLIO_PRO_CATEGORY
ROOT
JUX_PORTFOLIO_PRO_TAGS
Detectors & Diagnostics
We use cookies

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.